Diesel is often considered when stored fuel and independent standby power are priorities. Gas may fit when a reliable gas supply and the intended operating profile support it. Both require a project-specific load and site assessment.
Fuel type is only one part of the system decision. Availability, load profile, installation site, emissions and sound requirements, maintenance and integration into the existing infrastructure must be assessed together.
When does a diesel generator fit?
Diesel generator sets are frequently considered for standby, emergency and project applications where fuel is to be stored on site. Tank capacity, refuelling concept, fuel ageing, runtime, maintenance and local requirements must be included in the plan.
Selection must not be based on a kVA value alone. Load steps, motor starting, consumer structure, PRP/ESP operating profile, ambient temperature, altitude and sound limits influence the actual configuration.
When does a gas generator fit?
Gas generator sets may be suitable when natural gas or LPG is reliably available at the required quality and pressure. Gas type, supply reliability, gas train, installation concept, ventilation, exhaust routing and controls require project-specific coordination.
PRP and ESP for gas generators are also tied to the operating profile and conditions in the current manufacturer datasheet. An available gas connection alone does not establish suitability.
Natural gas supply at the site
Ask the gas supplier for the available gas quality and pressure at the proposed generator connection. Confirm what the supply can deliver during the intended operating hours, then compare it with the model’s fuel requirements. Compare the PSI natural gas range, Hyundai natural gas range and Scania natural gas range.
LPG storage and vaporisation
Establish where the LPG will be stored and how it will be replenished. Check the planned storage, vaporisation capacity and supply pressure for the expected operating profile and site conditions. Compare the PSI LPG range and the Hyundai LPG range.
Compare diesel and gas
This overview highlights the main planning differences. Final selection still depends on the load profile, site and manufacturer conditions.
| Criterion | Diesel | Gas |
|---|---|---|
| Fuel supply | On-site storage and a coordinated refuelling concept | Gas type, quality, pressure and reliable supply |
| Operating profile | Standby, prime or project operation according to the rating definition | Operating mode matched to gas supply and plant concept |
| Planning focus | Tank, autonomy, refuelling, emissions and sound | Gas connection, ventilation, controls and integration |
| Power ratings | PRP and ESP according to the current datasheet | PRP and ESP according to the current datasheet |
Data required for a reliable selection
Technical preselection requires the load profile, required PRP/ESP operating mode, voltage and frequency, site conditions, sound limits, fuel infrastructure, transfer or synchronisation concept and applicable project requirements.
- Consumers, peak loads, load steps and motor starting currents
- Standby, prime or project-specific operating profile
- Site, temperature, altitude, ventilation and sound attenuation
- Available diesel or gas infrastructure
- Required autonomy, transfer, parallel operation and controls
Technical basis
Current approved manufacturer datasheets and the actual project conditions govern preselection. Product values are not transferred between models or operating modes.
Sizing a diesel or gas generator depends on the load profile and the order in which loads are applied. Cummins explains how load steps and motor starts affect generator response.
Frequently asked questions
Is diesel always better for standby power?
No. Diesel is frequently used for standby power, but the supply concept, load profile, runtime, site and actual project requirements determine suitability.
Is an existing gas connection sufficient?
No. Gas type, pressure, quality, available volume, supply reliability and the plant concept must also be checked.
Can diesel and gas be compared by kVA alone?
No. PRP/ESP, load behaviour, motor starting, ambient conditions, sound, fuel supply and manufacturer conditions all belong in the comparison.
What information is required for a recommendation?
At least the load profile, operating mode, voltage, frequency, site, fuel supply, sound requirements and intended plant integration.
Classify your project technically
Send us the load profile, operating mode, site conditions and available fuel infrastructure. We support technical preselection.
Prepare enquiry